BERITA

Metode analisis uji paparan perekat ASTM D904 dalam cahaya buatan

ASTM D904 is a standard practice that provides guidance for adhesive samples exposed to artificial light to assess their light stability. The standard specifies test conditions, including light sources, exposure cycles and evaluation criteria, as well as the preparation of test samples and test procedures. The purpose of this standard is to provide a uniform and reliable method for evaluating the photostability of adhesives, which is important for a variety of applications, including product development, quality control and material selection. Itu...

Standar ASTM untuk menguji sifat cair pelapis

ASTM D281-12 (2016) Standard Test Method for Scraping paint-absorbing Oils with Scrapers ASTM D562-10 (2018) Metode Uji Standar Konsistensi Cat untuk Mengukur Satuan Krebs (KU) Viscosity Using a Stomer Type viscometer ASTM D869-85 (2015) Standard Test Method for Assessing the extent of paint Settlement ASTM D1200-10 (2018) Standard test method for Viscosity of Ford Viscosity cups ASTM D1210-05 (2014) Standard Test Method for Dispersion Fineness of Pigment-Vehicle Systems using Hegman type Gauges ASTM D1331-14 Standard Test Method for Surface and Interfacial Tension of Solutions...

ASTM Standard for Physical Properties of paint film

ASTM D522 / D522M-17 Standard test Method for bending tests of mandrel attached to Organic coatings ASTM D823-18 Standard specification for the production of films of uniform thickness of paint films, pelapis, and related products on test plates ASTM D968-17 Standard Test method for Abrasion Resistance of Dropped abrasives to Organic Coatings ASTM D1005-95 (2020) Standard Test Method for Measuring dry Film Thickness of Organic Coatings using a micrometer ASTM D1212-91 (2020) Standard Test Method for Measuring Wet Film Thickness of Organic Coatings ASTM D1474...

Gunakan viskometer putar untuk menguji viskositas pati

introduction The basic principle of measuring starch viscosity with rotary viscometer is to use the gelatinization behavior of the sample in a certain temperature range and measure its viscosity change by rotating viscometer. Saat suhu meningkat, sampel pati secara bertahap akan menjadi gelatin, sehingga mengubah viskositasnya. Viskometer putar dapat mengukur perubahan ini secara akurat dan memberikan data kuantitatif mengenai nilai viskositas. principle The gelatinization process of starch means that under heating conditions, partikel pati menyerap air dan mengembang dan lambat laun pecah, melepaskan pati...

Metode penentuan ketahanan lipat kertas dan papan

Makalah ini memperkenalkan secara rinci metode pengukuran lipatan kertas dan papan, termasuk uji lipat Schopper dan penggunaan meter lipat MIT. Makalah ini mencakup definisi resistensi lipat, struktur instrumen, Indikasi undervoltage catu daya, Kalibrasi instrumen, Prosedur Persiapan dan Pengujian Sampel. Metode Schober cocok untuk tes kertas ganda, Sedangkan metode MIT digunakan untuk menentukan jumlah lipatan kertas bolak -balik. Metode pengujian ini digunakan untuk mengevaluasi...

Analisis teknis uji kekuatan kupas 180° film perekat

In the application of adhesives, bond strength is one of the core indexes to measure the properties of adhesives. The peel strength test is an important means to evaluate the adhesion properties of adhesives, and the 180° peel strength test is widely used because it simulates the peel behavior in the real environment. Dalam makalah ini, the principle, method and application of 180° peel strength test in waterborne polyurethane adhesive are introduced in detail. 1, 180° peel strength test principle The 180°...

How to obtain altitude information with white light interferometer

一.What is white light? Visible light wavelength range 390nm-780nm, the shortest is violet light, followed by blue light, green light, yellow light, orange light, red light. White light is a composite light, and the wavelength of the light source of the white interferometer is generally around 500nm. 二.light interference 1. What is light interference Two coherent light sources with the same frequency, constant phase difference and consistent vibration direction can produce light interference. 2. How to generate light interference Through the beam splitter, one beam of light...

The advantage of white light interferometer to measure step height

1.High precision White light interferometer accuracy can reach sub-nanometer level Figure 1, "Coating Step Measurement" (Photo taken by NA-500, 50X) 2.Abundant multi-line measurement tools Fast selection of more cross sections than the probe type to ensure measurement stability; Rich functions, automatic measurement of the highest and lowest points, rata-rata, statistical analysis. Angka 2, "Wafer cutting step Depth" (Photograph by X-230, 20X) 3.Transparent products for height measurement Surfaces with reflectance as low as 0.02% can also be easily captured for point cloud imaging. Angka 3, "Ultra-smooth Glass mirror" (Photograph by EX-230,...