Touch screen high temperature Brinell viscometer
להשתמש
Using a coaxial center structure, using a small sample adapter, each measurement requires a very small sample size, temperature control quickly and accurately. It has many measuring parameters, rich display content, תפעול נוח, intuitive reading, high measuring precision, מהירות סיבוב, strong anti-interference performance, wide working voltage and so on. can replace the same type of imported instrument.
תכונות עיקריות:
- 1. adopts ARM technology, built-in Linux system. Operation interface is simple and clear, through the creation of testing procedures and data analysis, fast and convenient viscosity testing;;
- Accurate viscosity measurement: each measuring range is automatically calibrated by computer with high precision and small error;
- Display rich: בנוסף לצמיגות (dynamic viscosity and kinematic viscosity), there are temperature, קצב גזירה, מתח גזירה, measured value as a percentage of the full range value (graphic display), range overflow alarm, סריקה אוטומטית, maximum measurement range under the current rotor speed combination, תַאֲרִיך, זְמַן, וכו. The kinematic viscosity can be displayed under the known density to meet the different measurement requirements of users;
- Fully functional: can be timed measurement, בנוי בעצמו 30 groups of testing procedures, access to 30 groups of measurement data, real-time display viscosity Curves, printed data, curves, וכו ';
- Stepless speed regulation:
RV1T series:0.3-100 rpm, a total of 998 rotational speeds
RV2T Series:0.1-200 rpm,2000 rpm
- Shows the curve of shear rate to viscosity: can set the range of shear rate, real-time display on the computer; can also show the curve of time to viscosity
- Operating System in English and Chinese
Measurable in a very large range from 50 ל 80 million MPA.S, samples that can meet various high viscosity high temperature melts (e.g. hot melt adhesive, asphalt, פלסטיק, וכו ')
Optional ultra-low viscosity adapter (רוטור 0) can also measure the viscosity of paraffin wax, polyethylene wax if molten sample.
פרמטרים טכניים מפורטים:
דֶגֶם | RVDV-1T-H | HADV-1T-H | HBDV-1T-H |
Control / לְהַצִיג | 5-inch color touch screen | ||
מְהִירוּת/ R / min) | 0.3 – 100, Stepless speed,998 speeds available | ||
measuring range (mPa.s) | 6.4 – 3.3תקן פלסטיק Rotor No.0:6.4-1ק Rotor No.21:50-100ק Rotor No.27:250-500ק Rotor No.28:500-1תקן פלסטיק Rotor No.29:1K-2M | 12.8 – 6.6תקן פלסטיק Rotor No.0:12.8-1ק Rotor No.21:100-200ק Rotor No.27:500-1תקן פלסטיק Rotor No.28:1K-2M Rotor No.29:2K-4M | 51.2 – 26.6תקן פלסטיק Rotor No.0:51.2-2ק Rotor No.21:400-1.3תקן פלסטיק Rotor No.27:2K-6.7M Rotor No.28:4K-13.3M Rotor No.29:8K-26.6M |
Rotor | 21,27,28,29(ה) לא.0 (Optional) | ||
Sample dosage | Rotor No.0:21ml Rotor No.21: 7.8ml Rotor No.27: 11.3ml Rotor No.28: 12.6ml Rotor No.29: 11.5ml | ||
טעות מדידה | ± 1% (נוזל ניוטוני) | ||
repetitive error | ± 0.5% (נוזל ניוטוני) | ||
Show shear response / קצב גזירה | have | ||
פונקציית תזמון | have | ||
Real-time display Viscosity curve | Time-viscosity curve Temperature-viscosity curve (optional temperature sensor) (Optional data processing software shows shear rate and viscosity curves) | ||
צמיגות קינמטית | Density of samples to be entered | ||
measuring range | Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range | ||
Self-built Measuring Procedures | Save 30 קבוצות (including rotor, מְהִירוּת, טֶמפֶּרָטוּרָה, זְמַן, וכו ') | ||
Preservation of measurements | Save 30 סטים של נתונים (כולל צמיגות, טֶמפֶּרָטוּרָה, רוטור, מְהִירוּת, קצב גזירה, מתח גזירה, זְמַן, צְפִיפוּת, צמיגות קינמטית, וכו ')) | ||
printer interface | Print data, curves (need to buy printer) | ||
Computer output interface | RS232 | ||
working power supply | Viscometer mainframe: wide voltage operation (110 V/60 Hz or 220 V/50 Hz) Heating furnace and temperature control unit:220V50Hz | ||
outline dimension | 300 × 300 × 450 (מ"מ |
דֶגֶם | RVDV-2T-H | HADV-2T-H | HBDV-2T-H |
Control / לְהַצִיג | 5-inch color touch screen | ||
מְהִירוּת/ R / min) | 0.1 – 200, Stepless speed2000 speeds available | ||
measuring range (mPa.s) | 3.2 – 10תקן פלסטיק Rotor No.0:3.2-1ק Rotor No.21:50-500ק Rotor No.27:125-2.5תקן פלסטיק Rotor No.28:250-5תקן פלסטיק Rotor No.29:500-10תקן פלסטיק | 6.4 – 20תקן פלסטיק Rotor No.0:6.4-1ק Rotor No.21:150-1תקן פלסטיק Rotor No.27:250-5תקן פלסטיק Rotor No.28:500-10תקן פלסטיק Rotor No.29:1K-10M | 25.6 – 80תקן פלסטיק Rotor No.0:25.6-2ק Rotor No.21:200-4תקן פלסטיק Rotor No.27:1K-20M Rotor No.28:2K-40M Rotor No.29:4K-80M |
Rotor | 21,27,28,29(ה) לא.0 (Optional) | ||
Sample dosage | Rotor No.0:21ml Rotor No.21: 7.8ml Rotor No.27: 11.3ml Rotor No.28: 12.6ml Rotor No.29: 11.5ml | ||
טעות מדידה | ± 1% (נוזל ניוטוני) | ||
repetitive error | ± 0.5% (נוזל ניוטוני) | ||
Show shear response / קצב גזירה | have | ||
פונקציית תזמון | have | ||
Real-time display Viscosity curve | Time-viscosity curve Temperature-viscosity curve (optional temperature sensor) (Optional data processing software shows shear rate and viscosity curves) | ||
צמיגות קינמטית | Density of samples to be entered | ||
measuring range | Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range | ||
Self-built Measuring Procedures | Save 30 קבוצות (including rotor, מְהִירוּת, טֶמפֶּרָטוּרָה, זְמַן, וכו ') | ||
Preservation of measurements | Save 30 סטים של נתונים (כולל צמיגות, טֶמפֶּרָטוּרָה, רוטור, מְהִירוּת, קצב גזירה, מתח גזירה, זְמַן, צְפִיפוּת, צמיגות קינמטית, וכו ')) | ||
printer interface | Print data, curves (need to buy printer) | ||
Computer output interface | RS232 | ||
working power supply | Viscometer mainframe: wide voltage operation (110 V/60 Hz or 220 V/50 Hz) Heating furnace and temperature control unit:220V50Hz | ||
outline dimension | 300 × 300 × 450 (מ"מ |