חֲדָשׁוֹת

Operating rules for laboratory grinding and dispersing machines

The operating procedures of the laboratory grinding and dispersing machine can be carried out according to the following steps: עבודת הכנה: Ensure that the power connection of the laboratory grinding and dispersing machine is normal, and check whether all safety devices of the equipment are in good condition. Check the type and quality of grinding media (לְמָשָׁל. grinding beads) to ensure that they meet the test requirements. Prepare samples to be ground and dispersed, and prepare the appropriate solvent or medium as required. Operating rules...

Hydraulic disperser can not lift how to do?

If the hydraulic disperser does not rise or fall, זה יכול להיות בגלל הסיבות הבאות: Hydraulic system failure: Check the working state of the hydraulic system, including whether the hydraulic oil is enough, whether the hydraulic pump works normally, whether the hydraulic pipeline is blocked, וכו. If a fault is found, the relevant parts of the hydraulic system need to be repaired or replaced. Hydraulic valve failure: The lifting operation of the hydraulic disperser is usually controlled by the hydraulic...

הדבקה רטובה של צבע לטקס על מצע של אמייל אלקיד מבריק

משמעות ושימוש 5.1 צבע לטקס עשוי להיות נתון ללחות גבוהה, עיבוי או משקעים לאחר ציפוי משטחים פנימיים או חיצוניים. זה יכול לפעמים לגרום לאובדן הדבקה למצע עליו הם מיושמים. השיטה היא מדידה כמותית של הידבקות בין צבע לטקס למצע מבריק במקרה זה. טווח 1.1 שיטת בדיקה זו מכסה נהלים למדידת הידבקות של צבע לטקס למצע אמייל אלקיד מבריק על ידי קרצוף לאחר חשיפה לתנאי רטיבות. 1.2...

ASTM D5007-99-2017 “Standard Test Method for Changes in Wet-Dry Covering Power”

משמעות ושימוש 5.1 Many architectural paints, especially white and light paints, change significantly in film opacity as they dry. Increased coverage is sometimes associated with porosity and poor film integrity in conventional formulations. The reduction can lead to disappointing paint jobs. לָכֵן, the change in covering power from wet to dry is a property of great practical significance. 5.2 This test method can be used for paint specifications and as a brief procedure for assessment and quality control. ASTM D5007-99-2017 "Standard Test...

Corner Coating of Powder Coatings ASTM D 2967-2017

משמעות ושימוש 4.1 This test method measures the extent to which different coating powder materials cover sharp corners. כיסוי פינות מושפע מעובי פני השטח, טיקסוטרופיה, צמיגות נמס, מתח פני השטח, קצב ריפוי, וטמפרטורת היישום והריפוי. טווח 1.1 שיטת הבדיקה מורכבת מקביעת היחס בין עובי זוויתי (לִרְאוֹת 3.1.3) to surface thickness (לִרְאוֹת 3.1.4) of the powder coating applied to a particular surface thickness by dipping a preheated square rod into an aerated powder and curing the coating using...

ASTM ד 4217-2017 “Gelation Time of Thermosetting Powder Coatings”

משמעות ושימוש 4.1 This test method can be used to select coating powders that gel at specified temperatures for the required time. This method is not useful for determination of curing time. טווח 1.1 This test method determines the length of time required for a thermosetting coating powder to gel on a polished metal surface at a specified temperature (לְמָשָׁל. 204מעלות צלזיוס (400°F)). Gel time determination is a very simple method to characterize and quality control coating powders. למרות זאת, the gel time determined...

ral color card k5 and k7 difference

RAL color cards are a standard color reference system commonly used to describe and compare the colors of various objects. RAL color cards are available in several series, including the K5 and K7 series, and the differences between them are as follows: K5 Color card: The K5 color card is a series of RAL color cards, also known as the K5 Classic series. It contains 213 common colors and covers a wide gamut and hue, including gray, כְּחוֹל, יָרוֹק, אָדוֹם, צָהוֹב, orange...

Standard Test Method for Color of Clear Liquids (סולם פלטינה-קובלט)

Platinum-cobalt scale is a common standard test method for the color of transparent liquid, which is used for qualitative and quantitative evaluation of liquid color. The following is the basic principle and operation procedure of the platinum-cobalt scale: עִקָרוֹן: The platinum-cobalt scale is a set of liquid color standard solutions consisting of platinum and cobalt. Platinum-cobalt scales are adjusted by concentration gradient to obtain different color levels, from colorless gradually to different color depths. The color level of the liquid can be...