Viscosimètre à écran tactile
- La description
- Enquête
La description
Viscosimètre à écran tactile
Caractéristiques principales:
- Using ARM technology, built in Linux system. L'interface de fonctionnement est simple et claire, through the test program to create and dataAnalysis, rapid and easy to carry out the viscosity test;
- The viscosity measurement is accurate, each range is automatically calibrated with the computer, the accuracy is high, and the error is small;
- L’affichage de contenu riche: in addition to the viscosity, et la température, taux de cisaillement, contrainte de cisaillement, measurement for the full-scale value percentage (graphique), analyse automatique, overflow alarm range, the maximum measurement range, the rotor speed under the combination of the date, time and so on. And it can show the kinematic viscosity in the case of known density, great to meet different measurement requirements of users;
- Function is complete, can be measured regularly, 30 ensembles de procédures de test, access to the 30 ensembles de données de mesure, real-time display of viscosity curve, print data and curves, etc.;
- Pre – level meter, the level of direct and convenient adjustment
- Sonde de température en option, viscometer special constant temperature bath, tasse à température constante, imprimante, échantillons standards (standard oil viscosity) etc.;Widely used in all kinds of fluid need to measure viscosity. Including paint, Peinture, encrer, produits de beauté, pâte à papier, aliments, pétrole, amidon, solvent based adhesive, latex, biochemical products and so on.Paramètres techniques détaillés:
Modèle LVDV-1T Contrôle / mode d'affichage 5 écran tactile couleur en pouces speed(r/min) 0.3,0.6,1.5,3,6,12,30,60 0.5,1,2,2.5,4,5,10,20,50,100
measuring range mPa.s 0.6?? 2,000,000(0 ~ 4# rotor) 10~200,000(21/27/28/29# rotor)
Measurement of 10 below the ultra low viscosity to buy 0# rotor rotor 1 – 4#(configuration standard) 0#rotor (Select configuration)
21/27/28/29#rotor(Select configuration)
Erreur de mesure (Newton liquid) ±1% Repetition error (Newton liquid) ±0. 5% Fonction de synchronisation configuration standard Température measuring function
Interface de sonde de température standard (need to select the temperature probe configuration)
Fonction de numérisation automatique Automatic scanning and recommendation of the best combination of rotor and speed
Display the maximum measurement range The range of viscosity can be measured by the combination of the selected rotor and rotational speed. Contrainte de cisaillement / taux de cisaillement
afficher Display kinematic viscosité
Need to enter the density of the sample Establish measurement procedures Peut économiser jusqu'à 30 groupes (y compris le rotor, la vitesse, Température, temps, etc.)
Save measurement results Peut économiser jusqu'à 30 ensembles de données (y compris la viscosité, Température, rotor, la vitesse, taux de cisaillement, contrainte de cisaillement, temps, densité, viscosité cinématique, etc.) Viscosity time curve real-time display Imprimer Print data, courbe (standard print interface, should choose to buy a printer)
Constante temperature unit
Choix (including all kinds of special thermostat thermostatic cup viscometer.)
Source de courant 110V / 60Hz ou 220V / 50Hz Cote de contour 300 × 300 × 450(mm) Option:
- Ultra low viscosity adapter (0# rotor)
Un ensemble de trois pièces (rotor, seau d'échantillon,cadre de connexion)For the measurement of ultra low viscosity samples below 15mPa.S.
La quantité d'échantillon requise pour chaque mesure est de 18 à 20 ml ,La précision de la mesure est de 0,1 MPa.
- Small sample adapter
By 21#, 27#, 28#, 29# and the like rotor
barrel and connecting frame,
The sample size for each measurement is 18ml.
- Sonde de température (capteur de température)
High precision temperature measurement chip
with A/D conversion in American Production
Plage de mesure: 100 – 0
Précision de mesure: 0.1
- Micro-imprimante thermique
Peut être directement connecté au viscosimètre
imprimer des données
Courbe d'impression
5.Viscomeer Bath thermostatique spécial
DC0506N:
Écart de température: -5 à 100
Précision de contrôle de la température: 0.1
Source de courant: 220V, 50Hz
CH1006N:
Écart de température: room temperature and 10 à 100
Précision de contrôle de la température: 0.1
The circular opening can be placed 200ml beaker and direct viscosity
The external circulation function can also be controlled by the constant temperature liquid lead
To the outside of the constant temperature cup, pour répondre à différentes exigences de test