LS-542 Thickness Tester

  • La description
  • Enquête

LS-542 Thickness Tester

Utilisation

Thickness Tester is designed based on the mechanical contacting method, which effectively ensures standard and accurate test data and applicable to thickness test of plastic films, des draps, diaphragms, papier, foils, silicon wafers and other materials within specified range.

 

LS-542 Thickness Tester

Personnage

♦ Contact area and pressure are strictly designed according to standard requirements, while customization is also available

♦Automatic lifting presser foot facilitates to minimize system errors that caused by human factors during the test

♦ Manual or automatic operating mode for convenient test

♦ Automatic specimen feeding, specimen feeding interval, number of testing points and specimen feeding speed could be preset by the user.

♦ Displays the real-time data of maximum, le minimum, average and standard deviation value for data analysis

♦ Automatic statistics and printing functions are available which is convenient for the user to obtain the test results

♦ Equipped with standard block for system calibration to ensure uniform and accurate test data

♦ The instrument is controlled by micro-computer with LCD display, PVC operation panel and menu interface

♦ Equipped with RS232 port which is convenient for data transfer

Norme d'essai

ISO 4593、ISO 534、ISO 3034、Go/T 6672、Go/T 451.3、 Go/T 6547、ASTM D374ASTM D1777TAPPI T411JIS K6250JIS K6783JIS Z1702、 BS 3983、BS 4817

 

LS-542 Thickness Tester

Spécifications des applications

Applications de basePlastic Films, Sheets and Diaphragms
Paper and Paper Board
Foils and Silicon Wafers
Metal Sheets
Textiles and Non-woven Fabrics, par exemple. baby diapers, sanitary towel and other sheeting
Solid Electrical Insulating Materials
Applications étenduesExtended Test Range of 5mm and 10mm
Curved Presser Foot

 

Speicifcation

Plage d'essai0~2 mm (la norme)
0~6 mm, 10 mm (enduit de tige et autres outils pour le revêtement)
Résolution0.1 je suis
Test Speed10 times/min (Ajustable)
Test Pressure17.5±1 KPa (film)
50±1 KPa (papier)
Contact Area50 mm2 (film)
200 mm2 (papier)
Noter: Select one presser foot for film or paper; Customization is available
Specimen Feeding Interval0 ~ 1000 mm(Optionnel)
Specimen Feeding Speed0.1 ~ 99.9 mm/s
Instrument Dimension461 mm (L) Taille du réservoir 334 mm (W) Taille du réservoir 357 mm (H)
Source de courantAC 220V 50Hz
Poids net25 kg

Configuration standard
A Standard gauge block, professional l software, communication cable, measuring head

Nous contacter