- La description
- Enquête
Introduction-3nh YS6003 desktop Color spectrophotometer
YS6003 desktop spectrophotometer can accurately measure and express various color difference formulas and color indexes in a variety of color spaces. The built-in temperature sensor monitors and compensates the test environment to ensure more accurate measurement results. It is widely used in reflection samples, transparent samples color transfer and quality control in plastic electronics, peinture et encre, textile and garment printing, printing and other industries.
Features-3nh YS6003 desktop Color spectrophotometer
1, Haute configuration du matériel: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Grille concave.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable xenon lamp.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 3 measuring apertures: Φ 25.4mm/8mm/4mm.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm – 780nm.It can be used to test fluorescent samples with wide applicability and simple operation
7, Independent light source detector to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.
9, Multiple accessories, sample holders, fixation clamp, suitable to more working condition.
10, Big capacity data storage, for 20000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Specifications-3nh YS6003 desktop Color spectrophotometer
Modèle | YS6003 |
Géométrie optique | Refléter: de:8°, de:8°(éclairage diffus, 8-angle de vue en degrés);SCI (composant spéculaire inclus)/SCE (composante spéculaire exclue) ; Inclure les UV / source de lumière UV exclue; Transmission: de:0°, de:0° (diffuse illumination: 0° visualisation); SCI (composant spéculaire inclus)/SCE (composante spéculaire exclue) ; Brume(ASTM D1003); Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, encres, textiles, garments, impression et teinture, printing etc industries for color transfer and quality control. |
Intégration de la taille de la sphère | Φ154mm |
Source de lumière | 360 nm to 780 nm, Lumière LED combinée (5 million life span) |
Mode spectrophotométrique | Grille concave |
Chinois et anglais | 256 Capteur d'image CMOS à double matrice d'éléments d'image |
Gamme de longueurs d'onde | 360-780nm |
Intervalle de longueur d'onde | 10nm |
Largeur semi-bande | 10nm |
Plage de réflectance mesurée | 0-200% |
Ouverture de mesure | Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ30mm/Φ25mm; Remarque: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
Composant spéculaire | Réflectance: SCI&SCE / Transmission: SCI&SCE |
Espace colorimétrique | LABORATOIRE CIE,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Formule de différence de couleur | E*ab,E*uv,ΔE*94,ΔE*cmc(2:1),E*cmc(1:1),E*00, DINΔE99,ΔE(chasseur) |
Autre index colorimétrique | WI (ASTM E313, CIE/ISO, AATCC, chasseur), FAIS (ASTM D1925, ASTHME 313), DE (ASTM E313, CIE/ISO), MI (Indice de métamérisme), Solidité aux taches, Solidité de la couleur, Intensité de la couleur, Opacité, 8° Brillance,Gardner Index, Pt-Co Index, 555 Index, Brume(ASTM D1003) |
Angle d'observation | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Données affichées | Spectrogramme/Valeurs, Valeurs de chromaticité des échantillons, Valeurs/graphique de différence de couleur, RÉUSSITE/ÉCHEC Résultat, Décalage des couleurs |
Entrain de mesurer le temps | About 2.4s (Measure SCI & SCE about 5s) |
Répétabilité | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: dans 0.05%); Valeur de chromaticité:Φ25.4mm/SCI, Écart type dans ΔE*ab 0.01 ( When a white calibration plate is measured 30 fois à 5 second intervals after white calibration); Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: dans 0.06%); Valeur de chromaticité:Φ25.4mm/SCI, Écart type dans ΔE*ab 0.015 ( When a white calibration plate is measured 30 fois à 5 second intervals after white calibration). |
Erreur inter-instrument | Φ25.4mm/SCI, Within ΔE*ab 0.15 (Moyenne pour 12 Tuiles de couleur BCRA série II) |
Dimension | L*W*H=370x300x200mm |
Lester | Approx. 9.6kg |
Pouvoir | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 années, plus que 3 millions de mesures |
Affichage | 7-pouces LCD couleur TFT, Écran tactile capacitif |
Port de données | USB & Print serial port |
Stockage de données | Standard 1000 pièces, Goûter 20000 pièces |
Langue | Simplified Chinese, Traditional Chinese, Anglais, |
Environnement d'exploitation | 0~40℃, 0~85 % HR (pas de condensation), Altitude < 2000m |
Environnement de stockage | -20~50℃, 0~85 % HR (pas de condensation) |
Accessoire standard | Adaptateur secteur, Mode d'emploi, CD Disk(Logiciel PC), cable USB, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Porte-échantillon, 25.4 caliber, 8 caliber, 4 caliber |
Accessoire en option | Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Remarques: Les spécifications sont sujettes à changement sans préavis. YS6003 quality management software can only be used for data management |