Introduction-3nh YL4560 Non- contact benchtop spectrophotometer ISO7724-1,ASTM E1164
YL4560 spectrophotometer is a color measuring instrument with 45/0 optical geometry(45 éclairage en forme d'anneau, visualisation verticale), to achieve precise non-contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc, which is developed by 3nh independently with independent intellectual property.YL4560 non-contact benchtop spectrophotometer can be applied for accurate color analysis and transmission in laboratories and R & D industries; it can also be used for accurate color measurement and quality control of automated production lines; it is widely used in cosmetics, fruits and vegetables, hygiène alimentaire, plastic electronics, peinture et encre, impression, ceramics and other industries, and also for fluorescence sample measurement. Its unique innovative design can not only provide non-contact measurement scheme directly from the production line, but also ensure stable and high-precision measurement results.
YL4560 non-contact spectrophotometer will not touch the sample in the measurement process, to prevent damage to the sample, but also to avoid cross contamination.
PRODUCT FEATURES-3nh YL4560 Non- contact benchtop spectrophotometer ISO7724-1,ASTM E1164
1. non-contact, 45 / 0 geometric optical structure to measure the reflectance and chromaticity of objects;
2. The movable measuring head moves up and down according to the actual height of the measured object;
3. Large touch screen measurement interface, real-time display of measurement data, to realize more measurement functions;
4. Multiple measurement modes (échantillon, Écran tactile du testeur de rugosité de surface KR310, continuous statistical mode) can be selected to meet the personalized needs.
APPLICATION INDUSTRY-3nh YL4560 Non- contact benchtop spectrophotometer ISO7724-1,ASTM E1164
45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, hygiène alimentaire, plastic electronics, peinture et encre, impression, ceramics and other industries, and also for fluorescence sample measurement.
spécification
| Modèle | YL4560 |
| Géométrie optique | 45/0 méthode(45 éclairage en forme d'anneau, visualisation verticale);Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7,GB 2893,GB/T 18833 |
| Fonctionnalités | 45/0 non- contact benchtop spectrophotometer can achieve precise non- contact measurement between the measuring probe and the sample like liquids, sauces, powders, etc. It can be applied for accurate color analysis and transmission In laboratories and R & D industries; It can also be used for accurate color measurement and quality control of automated production lines; It is widely used in cosmetics, fruits and vegetables, hygiène alimentaire, plastic electronics, peinture et encre, impression, ceramics and other industries, and also for fluorescence sample measurement. |
| Source de lumière | Full spectrum LED light,UV light |
| Mode spectrophotométrique | Grille concave |
| Chinois et anglais | 256 Capteur d'image CMOS à double matrice d'éléments d'image |
| Gamme de longueurs d'onde | 400~700nm/10nm output |
| Plage de réflectance | 0~200 % |
| Ouverture de mesure | Φ20mm(Peut être personnalisé <20mm) |
| Non-contact Distance | 7.5mm |
| Hauteur de l'échantillon | 0~150mm |
| Distance Adjustment Method | Manual adjustment and automatic adjustment (test height can be stored) |
| Mode de mesure | Sample mode/QC Mode/Continuous statistics mode |
| Méthode de localisation | Camera Locating |
| Espace colorimétrique | LABORATOIRE CIE,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
| Formule de différence de couleur | E*ab,E*uv,ΔE*94,ΔE*cmc(2:1),E*cmc(1:1),ΔE*00,ΔE(chasseur) |
| Autre index colorimétrique | WI(ASTM E313,CIE/ISO,AATCC,chasseur),FAIS(ASTM D1925, ASTM 313),DE(ASTM E313,CIE/ISO), Indice de métamérisme MI,Solidité aux taches,Solidité de la couleur,Intensité de la couleur, Opacité |
| Angle d'observation | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2(FCF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
| Données affichées | Spectrogramme/Valeurs, Valeurs de chromaticité des échantillons, Valeurs/graphique de différence de couleur, Chromaticity Graph, Simulation de couleur, RÉUSSITE/ÉCHEC Résultat, Décalage des couleurs |
| Entrain de mesurer le temps | Environ 1,5 s |
| Stockage de données | Sample mode + Mode CQ: 40,000; Continuous statistics mode: 10,000 |
| Répétabilité | Réflectance spectrale: Standard deviation within 0.08% Valeur de chromaticité: Dans ΔE*ab 0.03 (Lorsqu'une plaque d'étalonnage blanche est mesurée 30 fois à 5 intervalles de secondes après l'étalonnage du blanc) |
| Erreur inter-instrument | Dans ΔE*ab 0.2(Moyenne pour 12 Tuiles de couleur BCRA série II) |
| Mode de mesure | Mesure unique, Mesure moyenne(2 ~ 99 fois) |
| Dimension | 330*250*370mm |
| Lester | À propos 10 kg |
| Source de courant | DC 24V, 3A Power Adapter |
| Illuminant Life Span | 5 années, plus que 3 millions de mesures |
| Écran d'affichage | 7″ TFT Capacitive Screen-touch Display |
| Port de données | USB/RS-232,Bluetooth®4.0 |
| Langue | Chinois simplifié,Chinois traditionnel,Anglais |
| Environnement de travail | Température: 0~40℃; Humidité: 0~85% (Pas de condensation); Altitude < 2000m |
| Environnement de stockage | Température: -20~50℃; Humidité: 0~85% (Pas de condensation) |
| Accessoire standard | Adaptateur secteur, Manuel de l'Utilisateur, cable USB, Standard Calibration Board, Black Calibration Cavity, |
| Remarques | Les spécifications sont sujettes à changement sans préavis. |