je. Vue d'ensemble de l'instrument de mesure des couleurs d'impression:
En contrôle et mesure des couleurs, densitomètres, les colorimètres et les spectrophotomètres sont les principaux outils pour imprimer la mesure des couleurs. Bien que ces trois instruments aient des fonctions différentes, ils utilisent tous réfléchi (ou transmis) lumière pour mesurer la couleur. En éclairant l'échantillon avec une source de lumière standard à l'intérieur de l'instrument, l'échantillon absorbe sélectivement, reflète, et diffuse la lumière, and the instrument’s photodetector detects the reflected light and compares it with the standard light source. When using a single-wavelength filter or spectrometer, the sensor will analyze the color and intensity according to the wavelength respectively, carry out information processing, and provide the required density value or colorimetry parameters and other data.
Densitomètre: Usually designed with 3 ~ 4 filtres (such as red, vert, bleu), each filter allows about 1/3 of the visible spectrum to reach the photodetector, it can measure the whole visible spectrum range, get the density value of yellow, magenta, vert. Density meters generally have built-in functions including: densité, ink overprinting rate, gray level, saturation, zone de points, tone error, contraste d'impression, etc. Parmi eux, measuring the density is an important function of the densitometer, the density value can directly reflect the thickness and concentration information of the ink on the printing sheet.
Demande d'instruments de mesure des couleurs dans l'imprimerie
Colorimeters: There are currently two types of colorimeters on the market: tristimulus value type and spectrometric type.
Tristimulus value colorimeters and densitometers are very similar in design, including filters for red, green and blue primary colors that break visible white light into the three primary colors, but there are two main differences:
1) The tristimulus colorimeter is designed to observe color and functions like the human eye, while the densitometer is designed to take into account the special sensitivity of the ink.
2) The three-stimulus colorimeter can process and calculate different color data (such as color space conversion, calculation of color difference, etc.), and can allow users to draw color coordinates in three-dimensional space, while the densitometer does not describe the color of this function.
Spectrophotometers, also known as spectrophotometers, divide the visible spectrum into very narrow intervals, with each interval representing a different wavelength part of the white light. Because the white spectrum can be divided into many small parts, spectrophotometers can collect more data and are therefore more accurate than densitometers. Par conséquent, this kind of spectrophotometer has better measurement repeatability. Similar to the tristimulus value colorimeter, the spectrophotometer can convert the measurement results into three disportable numbers. When accurate color reproduction is required, colorimeters are the more appropriate choice (although not as reliable as spectrophotometers), but in four-color printing applications, colorimeters have some limitations compared to densitometers, because densitometers can separately measure metrics related to four-color printing, such as density, zone de points, ink overprinting, etc., while colorimeters can only measure color.
Demande d'instruments de mesure des couleurs dans l'imprimerie
Spectrophotometers: Similar to colorimeters, spectrophotometers are divided into two types: filter type and dispersive type, and their measurement principle is similar to that of spectrophotometers. The visible spectrum is divided into small segments using narrowband filters (type de filtre) or diffraction gratings (dispersive type). The filter type instrument is similar to the densitometer except that the spectrophotometer has more filters inside and can achieve higher resolution in the spectrum. En outre, due to the simple design of the instrument, the filter type spectrophotometer is very rugged and can withstand the harsh environment of daily life. Cependant, dispersive spectrophotometers are very sensitive to collisions, fragile and expensive, which are not suitable for carrying and production use, and are suitable for operation in a laboratory environment.
All spectrophotometers are able to output the same data as colorimeters and also provide spectral curves. Each curve represents the color of each measurement, which can identify ink pigment components like fingerprints.
En conclusion, for the printing industry, instruments that combine chromaticity measurement and density measurement are good choices. Maintenant, such instruments have been developed and produced, such as Gretag SPM 100 spectrophotometer produced by Gretag company in Switzerland. Although these instruments are currently expensive, they represent the direction of color measurement development in the printing industry.
Demande d'instruments de mesure des couleurs dans l'imprimerie
Deux, the printing industry for the use of color measuring instrument requirements:
For colorimeters:
Light shape: in order to be able to flexibly locate on the measured print, and adapt to the measurement of large format printing.
The measurement geometry condition should be 45°/0° or 0°/45°; Standard light source is C or D65 light source; Apply CIE 2° small field of view standard observer (because in printing operation, the area of color evaluation is small).
The measuring aperture of the colorimeter should not be greater than 5mm. En général, the color blocks used for printing are less than 10mm², and the color blocks on the printing quality control strip are only 6mm². Surtout dans le cas où des images de correspondance continue des couleurs doivent être mesurées, l'ouverture de mesure ne doit pas être supérieure à 5 mm.
La valeur de sortie du colorimètre doit inclure des valeurs de couleur standard (comme XYZ) et devrait également être capable de générer les coordonnées spatiales de chromaticité CIE LAB et CIE LUV.
Demande d'instruments de mesure des couleurs dans l'imprimerie
Pour les densimètres:
Facile à utiliser et standard: dans l'expérimentation et la production, le contrôle qualité d’impression est toujours indissociable de l’utilisation du densitomètre, si chaque mesure et étalonnage est fastidieux et prend du temps, affectera inévitablement la vitesse et la précision. En outre, l'étalonnage du densitomètre doit être vérifié périodiquement à l'aide d'un appareil de réflexion dédié (ou transmission) échelle de gris ou échelle.
La sensibilité de l'instrument doit être adaptée à l'impression de la mesure des couleurs, generally CIE A light source, T state density. Because the T-state density is an objective physical measuring instrument designed for color separation and printing, the blue, green and red light of the T-state density meter are complementary colors of the three primary colors (jaune, magenta and green), which can well detect and control the allocation of the three primary colors and the relative thickness of the yellow, magenta and green ink layers in the process of color separation and printing.
The performance of the instrument should meet the requirements of the specification, including accuracy, répétabilité, reproducibility and internal consistency of the instrument. They should be capable of performance comparison and measurement outside the prescribed time.