- Deskrip
- Pagtatanong
LS-201-1 Programmable temperatura kahalumigmigan Chamber
Constant temperatura at kahalumigmigan pagsubok Chamber (W350x D350 x H400mm (49L))
Pamantayan sa Disenyo:
GB11158 | Mataas na temperatura Test Chamber Teknikal na Kondisyon |
GB10589-89 | Mababang temperatura Test Chamber Teknikal na Kondisyon |
GB10592-89 | Mataas na Mababang Temperatura Test Chamber Technical Condition |
GB/T10586-89 | Mamasa masang Heat Test Chamber Teknikal na Kondisyon |
GB/T2423.1-2001 | Mababang temperatura Test Chamber Test Mga Paraan ng Pagsubok |
GB/T2423.2-2001 | Mataas na temperatura Test Chamber Test Methods |
GB/T2423.3-93 | Mamasa masa Heat Test Chamber Mga Pamamaraan ng Pagsubok |
GB/T2423.4-93 | Mga Paraan ng Pagsusulit sa Pagpapalit ng Temperatura ng Pamamasa |
GB/T2423.22-2001 | Mga Pamamaraan ng Pagsubok sa Pagbabago ng Temperatura |
IEC60068-2-1.1990 | Mababang temperatura Test Chamber Test Mga Paraan ng Pagsubok |
IEC60068-2-2.1974 | Mataas na temperatura Test Chamber Test Methods |
GJB150.3 | Mataas na temperatura ng mga pamamaraan ng pagsubok |
GJB150.4 | Mga Paraan ng Pagsusulit sa Mababang Temperatura |
GJB150.9 | Mga Pamamaraan ng Pagsubok sa Tag init |
LS-201-1 Programmable Temperature Humidity Chamber
1. Aytem 2. Modelo | Benchtop Temperature and humidity test chamber LS-201-1 |
3. Function | It simulates the products in the chamber where the climate condition of different temperature and humidity, such as high-low operation and storage, temperature cycling, high-low temperature and high-low humidity, moisture condensation etc. to check its adaptability and changing performance. It’s required to conform to international regulation (IEC, JIS, GB, MIL…) to reach the consistency (including test schedule, condition, method) under the international standard. |
4. Halimbawang application | The chamber applies to: compatibility test for store, transportation and application of electric, electronic products, unit components, parts and other materials under high or low temperature. The following samples are prohibited to be tested and stored: – Inflammable , explosive and other volatile substances; – Corrosive substance; – Biont; – Strong electromagnetic emission source. |
5. Tomo, laki ng & timbang | |
5.1. Tomo 5.2. Internal size 5.3. Panlabas na sukat 5.4. Timbang | 49L W350 x D350 x H400mm W550 x D1100 x H950mm/W90 x D85 x H88cm 150KG |
6. Pagganap | |
6.1. Test condition | Temperatura:+25°C , Humidity: ≤85%, no samples in the chamber |
6.2. Paraan ng pagsubok | GB/T 5170.2-1996 Temperature test chamber GB/T5170.5-1996 Temperature and humidity test chamber (only temperature and humidity) |
6.3. Temperatura hanay | -20℃→+150℃ (mag-angkop) |
6.4. Temperatura pagbabago | ±0.5°C |
6.5. Temperature accuracy distribution | ±2.0°C |
6.6. Halumigmig saklaw | 20%~98%R.H (temperature at 20℃-85℃) |
6.7. Humid. pag-iiba | ±2.5%R.H. |
6.8. Humidity accuracy distribution | ±3.0%. |
6.9. Heat-up time | -20℃ → +150℃ Heat up for 2-4.0℃/min |
6.10. Cooling time | +150℃→ -20℃ Cooling for 0.7-1.0℃/min |
6.11. Load condition | Testing space is not more than 3/4 of the total space, no heating |
6.12. Sample holder | Stainless steel punching stencil |