Máquina de muestras de espacio de cabeza LCHS-20N
- Descripción
- Investigación
Descripción
LCHS-20N Automatic Headspace Sampler Device
Caracteristicas:
1. 7-inch touch color screen is adopted to automatically realize pressure, muestreo, muestreo, análisis, backblow cleaning and other functions through time programming;
2. The number of headspace bottle stations is as many as 20, with fast heating speed, high temperature control precision and small gradient;
3. The screen displays the status of the time process, the status of the work and the function of the work prompt, which greatly facilitates the operation and use of the user;
4. Equipped with external loading gas regulation system, without any modification and change of GC instrument, can be carried out headspace sampling analysis, can also choose the original instrument carrier gas, so that the installation becomes very simple;
5. The pressure balance injection technique was used to realize the symmetrical narrow chromatographic peak shape in headspace injection;
6. Transmission tube and sampling valve have automatic backblowing function to avoid sample residue and cross contamination;
7. Para el análisis de sustancias activas., Se puede seleccionar un tubo de cuarzo elástico como tubo de transferencia de muestras.;
8. La cantidad de inyección se puede ajustar en cualquier momento según la concentración de la muestra a analizar por el cliente.;
9. Convenient syringe needle replacement, can be connected to all types of GC injection ports at home and abroad;
10. The structure design of the machine is reasonable, hermoso, generoso y práctico;
11. Microcomputer program control, las funciones principales son:
⑴ Method parameter setting, real-time working state, three-way temperature control, each running time;
(2) Área de muestra, sample valve system and sample transmission pipe, three separate heating and temperature control;
(3) Set the control program and press the Start button to finish the whole sample analysis automatically;
(4) The chromatograph can be synchronously started, workstation, can also be used to start the device by external procedures.
Parámetros técnicos:
1. Rango de control de temperatura del área de muestra.:
Set a maximum heating power of 600W at room temperature -300 ℃ con un incremento de 1 ℃;
2. Rango de control de temperatura del sistema de muestreo de válvulas.:
Set a maximum heating power of 120W at -180 ℃ at room temperature with an increment of 1℃;
3. Temperature control range of sample transfer pipeline:
The maximum heating power is about 100W at -180 ℃ at room temperature, with an increment of 1℃.
(Para una operación segura, 24V low-voltage power supply is adopted for temperature control of transmission pipeline)
4 precisión del control de temperatura: < ±0,5 ℃;
5. gradiente de control de temperatura: < ±0,5 ℃;
6. Estación de botellas Headspace: 20;
7. Especificaciones de la botella de espacio de cabeza: optional 20ml, 10GB.10587-89,CNS.4158,CNS.4159,CASO (50ml and other specifications can be customized);
8. Repetibilidad: RSDS ≤3% (etanol en 200 ppm de agua);
9. Modo de control de cantidad de muestra: tiempo de muestreo y control de presión cantidad de muestreo;
10. Rango de presión de inyección: 0 ~ 0,4 MPa (continuamente ajustable);
11. Flujo de limpieza por retroceso: 0 ~ 400ml/minuto (continuamente ajustable);
12 tamaño efectivo del instrumento: 420×220×380mm;
13. Weight of the instrument: ≥10 litros/min capacidad del tanque de agua a temperatura constante 15 kg.