Touchscreen-Viskosimeter
Haupteigenschaften:
- Using ARM technology, built in Linux system. Die Bedienoberfläche ist einfach und klar, through the test program to create and dataAnalysis, rapid and easy to carry out the viscosity test;
- The viscosity measurement is accurate, each range is automatically calibrated with the computer, the accuracy is high, and the error is small;
- Der Rich-Content wird angezeigt: in addition to the viscosity, und Temperatur, Scherrate, shear stress, measurement for the full-scale value percentage (Grafik), Automatisches Scannen, overflow alarm range, the maximum measurement range, the rotor speed under the combination of the date, time and so on. And it can show the kinematic viscosity in the case of known density, great to meet different measurement requirements of users;
- Function is complete, can be measured regularly, 30 Sätze von Testverfahren, access to the 30 VERWENDEN, real-time display of viscosity curve, print data and curves, usw.;
- Pre – level meter, the level of direct and convenient adjustment
- Optional temperature probe, viscometer special constant temperature bath, Tasse mit konstanter Temperatur, Drucker, standard samples (standard oil viscosity) usw.;Widely used in all kinds of fluid need to measure viscosity. Including paint, Farbe, Tinte, Kosmetika, paper pulp, Lebensmittel, Öl, starch, solvent based adhesive, latex, biochemical products and so on.Detailed technical parameters:
Modell LVDV-1T Kontrolle / Anzeigemodus 5 Zoll-Farb-Touchscreen speed(r/min) 0.3,0.6,1.5,3,6,12,30,60 0.5,1,2,2.5,4,5,10,20,50,100
measuring range mPa.s 0.6~ 2,000,000(0 ~ 4# Rotor) 10~200,000(21/27/28/29# Rotor)
Measurement of 10 below the ultra low viscosity to buy 0# Rotor Rotor 1 – 4#(standard configuration) 0#rotor (Select configuration)
21/27/28/29#rotor(Select configuration)
Measurement error (Newton liquid) Bild Repetition error (Newton liquid) ±0. 5% Timing function Standardkonfiguration Temperatur measuring function
Standardschnittstelle für Temperaturfühler (need to select the temperature probe configuration)
Automatic scanning function Automatic scanning and recommendation of the best combination of rotor and speed
Display the maximum measurement range The range of viscosity can be measured by the combination of the selected rotor and rotational speed. Shear stress / Scherrate
Anzeige Display kinematic Viskosität
Need to enter the density of the sample Establish measurement procedures Can save up to 30 Gruppen (including the rotor, Geschwindigkeit, Temperatur, Zeit, usw.)
Save measurement results Can save up to 30 Datensätze (including viscosity, Temperatur, Rotor, Geschwindigkeit, Scherrate, shear stress, Zeit, Dichte, kinematische Viskosität, usw.) Viscosity time curve real-time display Drucken Print data, Kurve (standard print interface, should choose to buy a printer)
Constant temperature unit
Optionen (including all kinds of special thermostat thermostatic cup viscometer.)
Energieversorgung 110V. / 60Hz oder 220V / 50Hz Outline dimension 300 × 300 × 450 (mm) Möglichkeit:
- Ultra low viscosity adapter (0# Rotor)
Ein Set bestehend aus drei Teilen (Rotor, Probeneimer,Verbindungsrahmen)For the measurement of ultra low viscosity samples below 15mPa.S.
Die für jede Messung erforderliche Probenmenge beträgt 18–20 ml ,Die Messgenauigkeit beträgt 0,1 mPa.S
- Small sample adapter
By 21#, 27#, 28#, 29# and the like rotor
barrel and connecting frame,
The sample size for each measurement is 18ml.
- Temperaturfühler (Temperatursensor)
High precision temperature measurement chip
with A/D conversion in American Production
Eine neue Batterie kann länger als ununterbrochen verwendet werden: 100 – 0
Eine neue Batterie kann länger als ununterbrochen verwendet werden: 0.1
- Mikro-Thermodrucker
Can be directly connected with the viscometer
print data
Print curve
5.Viscometer special thermostatic bath
DC0506N:
Temperaturbereich: -5 zu 100
Temperature control precision: 0.1
Energieversorgung: 220V., 50Hz
CH1006N:
Temperaturbereich: room temperature and 10 zu 100
Temperature control precision: 0.1
The circular opening can be placed 200ml beaker and direct viscosity
The external circulation function can also be controlled by the constant temperature liquid lead
To the outside of the constant temperature cup, to meet different test requirements