- Beschreibung
- Anfrage
LS-202-4 UV-Lampen-Alterungstestkammer
Profil.
The UV Accelerated weathering test chamber simulates damage caused by solar ultraviolet light, and the material is subjected to weather resistance test by exposing the sample to light under controlled high temperature. It uses ultraviolet light tubes to simulate the effects of sunlight. In just a few days or weeks, the chamber can reproduce damage that can take months or even years outside, including fading, color changes, tarnishing, Kreide, knacken, knacken, wrinkling, Blasenbildung, embrittlement, Kraftreduzierung, oxidation, usw., can be used to select new materials, improve existing materials, or evaluate changes in material formulations. 4 pieces together (UVA-340 und UVB-313 optional).
LS-202-4 UV-Lampen-Alterungstestkammer
1.Haupttechnische Parameter | |
Artikel | Alterungstestkammer für UV-Lampen |
Modell | LS-202-4 |
Innengröße | W1140 X H350 x D400mm |
Außengröße | W1300 X H500 x D500mm |
Regler | LCD-7-Zoll-Touchscreen-Controller, mit programmierbarer Temp., feucht., UV(Sonne), und Zeit und Fix-Modus von 2 Laufmodi. USB-Schnittstelle Bedientaste Alarmanzeige Bestrahlungstimer |
Temp. Steuermodus | PID-Selbsteinstell-SSR-Steuerung |
Temp. Bereich | RT+10℃ ~ 70℃ (einstellbar) |
Temp. Abweichung | ±2,0℃ |
Temp. Fluktuation | ± 0,5 ℃ |
Temp. Gleichmäßigkeit | ± 1 ℃ |
Temp. Fluktuation | ± 0,5 ℃ |
Achsabstand zwischen Lampen | 75mm±15mm |
Distance between samples and lamps | 100 ~ 50mm±30mm |
Irradiation level | ≤1.1W/m2 einstellbar |
Einstellung | Testzeitraum für Temp., irradiation can be adjustable |
Bestrahlungslampe | UVA-340, L = 1200 / 40W, 4Stck (average service life: 1600Std) |
Temp. Kontroll-Methode | PID selbsteinstellbare SSR-Regelung |
UV Wavelength | UVA-340: 315~400nm; |
Testzeit | 0~999 H 99 Mindest (einstellbar) |
Black board Temp. | 50℃ ~ 70℃ (temperature inside the chamber plus 20℃ ~ 25℃) |