- Beschreibung
- Anfrage
CS-810 Transmissions-Spektralfotometer
CS-810 Transmittance spectrophotometer is good performance and specially designed for testing the transparent material’s transmittance, absorbance, chromaticity value and other parameters.
The instrument adopts the geometry of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-test calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value △E*ab 0.015.
CS-810 Transmissions-Spektralfotometer
Hc41c6b57d8c643949b5cdf3c23024046q
- 1.D\0 Geometry
- 2.It is suitable for testing clear, transparent and translucentproducts such as glass, Öl, plastic and other materials color.
- Adopt UV enhanced silicon photodiode
Extend the transmittance measurement range from 0~100% to 0~200%
- It can also be used for measure APHA/Pt-Co, Gärtner,ASTM-Farbe, Yellowness Index for liquidand transparent materials.
- Color QC software
Our spectrophotometer comes with free color QC software, which is applicable in various industries for management of color data. It is used for store test result, generate test report and print test report after connect with printer.
CS-810 Transmissions-Spektralfotometer
6.Technische Daten
Art | CS-810 |
Erleuchtung | d/0(Diffuse Beleuchtung, 0°viewing) Optische SCS-Engine(light splitting and integration system),( konform zu CIE Nr.15, ISO 7724/1, ASTM E1164,DIN 5033 Teil7, JIS Z8722 Condition c standards) |
Größe der Ulbrichtkugel | 40mm,Alvan diffused reflection surface coating |
Beleuchtung Lichtquelle | CLEDs(entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wellenlängenbereich | 400-700nm |
Wellenlänge Tonhöhe | 10nm |
Half Band Width | 5nm |
Reflexionsbereich | 0-200% |
Reflexionsauflösung | 0.01% |
Beobachterwinkel | 2°/10° |
Leuchtmittel | EIN,C.,D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 CWF,U30, DLF,NBF,TL83, TL84 |
Data being displayed | Transmittance graph/value, chromatic value, Farbunterschiedswerte, color assessment results, Farbtendenz, history color value simulation, manual input standard sample, generate measurement reports |
Measurement time interval | 1 zweite |
Measurement time | 1 zweite |
Color spaces | CIE-L * a * b,L*C*h,CIE-L*u*v, XYZ, Yxy, Transmission, Hunter-lab |
Color difference formulas | ΔE*ab, E*CH, E*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), E*94, E*00 ΔE*ab (Jäger) |
Other indices | WI(ASTM E313-10, ASTM E313-73, CIE / ISO, AATCC, Jäger, Taube Berger, Ganz, Stensby), YI(ASTM D1925,ASTM E313-00, ASTM E313-73), Farbton(ASTM E313-00,CIE,Ganz) , GENAU HIER, Fr-Co, Gärtner, Saybolt, Astm color |
Wiederholbarkeit | Transmission : Standardabweichung innerhalb 0.08% |
Chromaticity values: Δ E*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum: 0.03) | |
Schnittstelle | USB |
Datenspeicher | mass storage |
Light source Lifetime | 5 Jahre, 1.5 Millionen Tests |
Größe | 475*340*150mm(leicht lesbare Daten) |
Gewicht | about 7kg |
Work temperature range | 0~45℃, relative Luftfeuchtigkeit 80% or below( at 35°C ),keine Kondensation |
Lagertemperaturbereich | -25bis 55℃,relative Luftfeuchtigkeit 80% or below(at 35°C ), keine Kondensation |
Standardzubehör | Power adaptor , color QC software, driving software, USB-Kabel, black calibration tile, 40*10mm cuvette |