Introduction-3NH YS6010 benchtop grating spectrophotometer

YS6010 is a benchtop grating spectrophotometer which is developed by 3nh independently with independent intellectual property. YS6010 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6010 ideal for color analysis within R&D and laboratory environments.

1-1P504105Z55D[1].jpg

Features-3NH YS6010 benchtop grating spectrophotometer

1, Hohe Hardwarekonfiguration: 7 inches TFT Color Capacitive Touch-screen Display; Konkaves Gitter.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.

7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9. A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions;

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Anwendungsindustrie

YS6010 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, wie zum Beispiel Kunststoffe, Elektronik, Farbe und Tinte, Drucken, garments, Drahtgewickelte Stäbe, Papier-, auto, medizinisch, Kosmetika, Lebensmittel, science institutes, laboratories.

Technical Specification-3NH YS6010 benchtop grating spectrophotometer

 

ModellYS6010 Benchtop Spectrophotometer
Optische GeometrieReflektieren: von:8°, von:8°(diffuse Beleuchtung, 8-Grad Betrachtungswinkel) ;
SCI (spiegelnde Komponente enthalten)/SCE (spiegelnde Komponente ausgeschlossen) ; UV einschließen / ausgeschlossene UV-Lichtquelle
Transmission: von:0°, von:0° (diffuse illumination: 0° viewing) ;
SCI (spiegelnde Komponente enthalten)/SCE (spiegelnde Komponente ausgeschlossen) ; UV einschließen / ausgeschlossene UV-Lichtquelle;
Dunst(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
AnwendungIt is used for accurate analysis and transmission of laboratory color. Apply in paints, Tinten, Drahtgewickelte Stäbe, garments, Drucken und Färben, printing etc industries for color transfer and quality control.
Größe der integrierenden KugelΦ154mm
Lichtquelle360 nm zu 780 nm, Kombiniertes LED-Licht, 400nm cut-off light source
Spektrophotometrischer ModusKonkaves Gitter
Sensor256 Bildelement-Doppelarray-CMOS-Bildsensor
Wellenlängenbereich360-780nm
Wellenlängenintervall10nm
Halbbandbreite10nm
Gemessener Reflexionsbereich0-200%
Blende messenReflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
Anmerkung: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Spiegelnde KomponenteReflexion: SCI&SCE / Transmission: SCI&SCE
FarbraumCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
FarbdifferenzformelE * ab ,E * uv ,E * 94 ,E * cmc(2:1) ,E * cmc(1:1) ,E * 00 , DINΔE 99 ,E (Jäger),
Anderer kolorimetrischer IndexWI (ASTM E313, CIE / ISO, AATCC, Jäger),
YI (ASTM D1925, ASTHMA 313),
TI (ASTM E313, CIE / ISO),
MI (Metamerism Index),
Färbebeständigkeit, Farbechtheit, Farbstärke, Opazität,
8° Glanz,Gardner Index, Pt-Co Index, 555 Index, Dunst(ASTM D1003)
Beobachterwinkel2°/10°
LeuchtmittelD65, A,C.,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Angezeigte DatenSpektrogramm/Werte, Proben der Chromatizitätswerte, Farbdifferenzwerte/Grafik, PASS/FAIL-Ergebnis, Farboffset
MesszeitAbout 2.4s (SCI messen & SCE about 5s)
WiederholbarkeitSpektrale Reflexion: Φ25.4mm/SCI, Standardabweichung innerhalb 0.05% (400 nm zu 700 nm: innerhalb 0.04%)
Farbwert:Φ25.4mm/SCI, Standardabweichung innerhalb von ΔE * ab 0.02 ( Wenn eine Weißkalibrierplatte gemessen wird 30 mal um 5 Sekundenintervalle nach der Weißkalibrierung) Spectral Transmittance: Φ25.4mm/SCI, Standardabweichung innerhalb 0.05% (400 nm zu 700 nm: innerhalb 0.04%)
Farbwert:Φ25.4mm/SCI, Standardabweichung innerhalb von ΔE * ab 0.03 ( Wenn eine Weißkalibrierplatte gemessen wird 30 mal um 5 Sekundenintervalle nach der Weißkalibrierung)
Inter-Instrument-FehlerΦ25.4mm/SCI, Innerhalb von ΔE*ab 0.15
(Durchschnitt für 12 Farbfliesen BCRA Serie II)
AbmessungenL*W*H=370x300x200mm
GewichtApprox. 9.6kg
LeistungAC 24V, 3A Power adapter power supply
Lebensdauer der Leuchtmittel5 Jahre, mehr als 3 Millionen mal Messungen
Anzeige7-Zoll TFT-Farb-LCD, Kapazitiven Touchscreen
DatenschnittstelleUSB & Print serial port
DatenspeicherStandard 2000 Stck, Stichprobe 20000 Stck
SpracheVereinfachtes Chinesisch, Traditional Chinese, Englisch,
Betriebsumgebung0~40℃, 0~85%RH (keine Kondensation), Höhe < 2000ich
Speicherumgebung-20~50℃, 0~85%RH (keine Kondensation)
StandardzubehörNetzteil, Benutzerhandbuch, CD Disk(PC-Software), USB-Kabel, Standard Calibration Board, Kavität für die Schwarzkalibrierung, Transmission black baffle, Beispiel halter, 25.4 caliber, 8 caliber, 4 caliber
Optionales ZubehörMikrodrucker, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components