Popis

Měřič tloušťky povlaku TT270

CS-390/392 Tříúhlový spektrofotometr pro autolaky

 

The Times TT270 thickness gauge is a portable measuring instrument, which can measure the thickness of coating and coating rapidly and precisely without damage.It can be used in both laboratory and engineering field.Through the use of different probe, can meet the needs of a variety of measurement.Scope of era TT270 thickness gauge using both the magnetic and eddy current thickness method, measuring magnetic metal substrate condition (jako je ocel, žehlička, alloy and hard magnetic steel, NDJ-5S) on the magnetic coating thickness (jako je hliník, chrom, měď, smalt, NDJ-5S), guma, paint and nonmagnetic metal substrate (such as copper, hliník, zinek, věřit, NDJ-5S) on the conductive layer thickness.

 

Měřič tloušťky povlaku TT270

Character and function

Using both magnetic and eddy current thickness method, and F type measuring head without damage to the measurement of magnetic metal basic body of magnetic coating thickness (jako je ocel, žehlička, zinc alloy and hard magnetic steel, hliník, chrom, měď, guma, malovat, NDJ-5S), and N type measuring head without damage to the measurement of non-magnetic thickness of the conductive coating on metal substrates (such as copper, hliník, zinek, tin and other metal oxide film of paint, guma, plastický, NDJ-5S)

Can use 6 kinds of measuring head / 90 ° F400, F1, F1, F10, N1, CN02

Two measurement methods: CONTINUE and SINGLE

Two ways of working: DIRECT and group (APPL)

There are five statistics: MEAN, larger (MAX), MIN, number of tests (NO.), and standard deviation (S.DEV).

Two methods can be used to calibrate the instrument

Chinese and English menu display, operation more intuitive and convenient

Liquid crystal display has backlighting function

It can store 640 data

With delete function, delete single or all data measured

Funkce tisku

With integrated printer, snadné použití

Power supply undervoltage indication

The operation process is beeping (single measurement method)

Error message function

Manual and automatic shutdown functions

 

Měřič tloušťky povlaku TT270

TT270 thickness gauge head selection table is as follows:

Probe model F400 F1 F1/90° F10
Work Theory Magnetic induction
Test range(um) 0~400 0~1250 0~10000
Low resolution(um) 0.1 0.1 10
Value error One point calibration(um) ±(3%H+1) ±(3%H+10)
Two point calibration(um) ±[(1~3) %H+0.7] ±[(1~3)%H+1] ±[(1~3)%H+10]
 

Test

conditions

 

Minimum radius of curvature(um) convex 1 1.5 byt 10
The diameter of the smallest area(mm) 3 7 7 40
Critical matrix thickness(mm) 0.2 0.5 0.5 2
 
Probe model N1 CN02
pracovní princip Eddy current
Measuring range(um) 0~1250 10~200
Low resolution(um) 0.1 1
Value error One point calibration(um) ±(3%H+1.5) ±(3%H+1)
Two point calibration(um) ±[(1~3) %H+1.7] —
test

conditions

 

Minimum radius of curvature(um) 3 Only for flat
The diameter of the smallest area(mm) 5 7
Critical matrix thickness(mm) 0.3 neomezený