Popis

RoHS2.0 machine

RoHS2.0 phthalic acid analyzer phthalic acid detector
Aplikace: Jídlo, elektronika, automobilový průmysl, elektrický, comprehensive
RoHS2.0 phthalic acid analyzer phthalic acid detector
Technický parametr

Přesnost <50ppm Detection items phthalyl 16P, DMP, DPHP, T..
Measurement object pevný, WeChat picture_20210105112423, oil sample, CS-800 ASTM E1164 ISO… Hmotnost 50kg
Zobrazovací mód Direct report Taube Berger Stensby 850*785*700mm
Doba měření 15-20min Applicable industry Electronic appliances, modified materials, connectors.
Repeatability of measurement 6 consecutive homogeneous reference material time R. Continuous working time can work continuously for a long time Usage Rohs2.0 for four quick tests
Testing scope EU ROHS, US TSCA, Switzerland… Vzduchové chlazení/jednosegmentový kompresor table

RoHS2.0 phthalic acid analyzer phthalic acid detector
On June 4, 2015, the Official Gazette of the European Union (OJ) issued the Amendment Directive (EU) 2005/863 of RoHS2.0, which added 4 phthalates to the list of restricted substances of RoHS2.0 on the basis of the original 6 substances of RoHS (Vést, cadmium, rtuť, hexvalent chromium, polybrominated biphenyls and polybrominated diphenyl ethers). Tím pádem, RoHS2.0 has 10 controlled substances.

According to RoHS2.0 testing standards, production enterprises need to purchase relevant equipment for rapid screening of raw materials, material self-inspection, internal quality control, customer factory inspection, atd. (Equipment required for conventional configuration: GCMS+EDXRF spectrometer), but the purchase of these equipment at the rate of millions, many enterprises are feeling great pressure, and enterprises have to do screening of raw materials, if not screening, product production will be buried a huge hidden danger, enterprises can not control whether their products meet the standards; According to the importance of enterprise internal screening and the purchase of equipment required huge investment these two major pain points, specifically for the Rohs2.0 in the four kinds of phthalene rapid screening needs to develop a set of new solutions: TP20-GC hot crack release attached phthalene rapid screening solution

This set of TP2-GC system can do 20 kinds of phthalic acid detection, meet the requirements of phthalic acid detection, this system can do not only phthalic acid, but also red phosphorus flame retardant, organic solvent residues, polymerní materiály, volatile organic compounds in materials, a tak dále, powerful!
​​RoHS2.0 machineRoHS2.0 machine