Retence světla povlakem a způsob jeho testování

Retence světla povlakem a způsob jeho testování

Povlaky hrají důležitou roli v různých aplikacích, nejenže dodává výrobku krásný vzhled, ale také převzetím úkolu chránit substrát. Během používání filmu, bude ovlivněna řadou faktorů, včetně vnějších sil, světlo, tepla a elektřiny. Mezi nimi, působení světla má významný vliv na světelnou retenci filmu. This paper will introduce the light retention of the film and its detection methods to meet the needs of different products.

Gloss retention of the film
The gloss retention of the film refers to the ability of the film to maintain its original luster under exposure to light. This performance is critical in a variety of applications, as maintaining shine not only makes the product look more attractive, but also extends the life of the film. In order to evaluate the light retention of the film, it is usually measured by the loss of light rate, which is the ratio of the shine after irradiation to the shine before irradiation.

Metoda detekce
The light retention of the coating film can be determined by the provisions of GB/T9754-2008 “Determination of 20°, 60° and 85 mirror gloss of the color paints and varnishes without metallic pigments”. Here’s how to do it:

Prepare the coating sample to be tested.

Cover part of the template to ensure that the part under test is not exposed to light.

The sample is exposed to sunlight or artificial light for a certain period of time to simulate the actual conditions of use.

The gloss values of the unirradiated and irradiated parts were determined by photoelectric gloss meter.

Calculate the loss of light, to je, the shine value after exposure divided by the shine value before exposure.

According to the value of the loss of light, the light retention of the film can be divided into different levels:

The loss of light rate of less than 5% is 0, indicating that the film has excellent light retention and almost no gloss loss.

5% na 20% is grade 1, indicating that the coating has good light retention and small gloss loss.

21% na 50% is grade 2, indicating that the gloss retention of the film is general and the gloss loss is moderate.

51%~80% is grade 3, which means that the light retention of the film is poor, and the luster is significantly weakened.

Více než 80% is grade 4, indicating that the light retention of the film is very poor, and the luster is seriously damaged.

Retence světla povlakem a způsob jeho testování

Oblast použití
The light retention test of the coating film has a wide range of applications in various industries, especially in areas that require product appearance to maintain a certain level, such as automobile manufacturing, furniture manufacturing, architectural decoration, atd. By testing the gloss retention of the coating, manufacturers can better understand the performance of their products and ensure that the product will maintain its appearance and quality during use.

The light retention of the film is one of the important indicators of the appearance and performance of the product, and it can be affected by light exposure, so it needs to be quantitatively tested. GB/T9754-2008 specifies the detection method of the light retention of the coating film. By measuring the loss of light, the light retention of the coating film can be divided into different levels. This test method is of great significance in a variety of applications, helping manufacturers to ensure that their products can maintain their luster in practical use, improving the competitiveness and quality of their products. Proto, výzkum a testování světelné retence nátěrového filmu má velký význam v nátěrovém průmyslu.