BGD 159 Digital Cone And Plate viscometer

  • وصف
  • تحقيق

BGD 159 Digital Cone And Plate viscometer

وصف

Most of paint and coatings are non-Newtonian fluids, its viscosity would show typical changes when applied with roller, brush or spray gun under high shear rates.

BGD 159 series Cone and Plate Viscometers designed by ISO 2884, ASTM D 4287 and BS 3900, can offer from 10,000S-1 to 12,000S-1 shear rates.

 

BGD 159 Digital Cone And Plate viscometer

المميزات

◆ 7 inch touch screen with powerful human-computer interactive interface and rich information, سهل تنفيذه

◆ Interchangeable cones, simple to install and easy to clean

◆ Choice of shear rate. Standard speeds include 750 و 900 rpm to provide shear rate at 10,000 sec-1.

◆ only need small sample amount(< 1 mL), simplifies testing

◆ Build-in PT100 temp. probe

◆ ARM chip processor and Gigabit Ethernet port ensure higher data processing speed and rapid& stable data transfer

◆ New designed durable axle, anti-static shell and metal lifter

◆ Come with heating and temp. control system, can set sample plate temperature from -5°C to 120°C or RT+5°C to 300°C

◆ Variety of viscosity units and auto switch between dynamic and kinematic viscosity

◆ Calibration by usertemperature and correction factor protected by password

How to choose your suitable Viscometer?

1. Specify one speed or shear rate if this is required for your method.

2. Indicate viscosity range.

3. Select the temperature range that best suits your application: -5°C to 120°C (L Type) or RT+5°C to 300°C (H Type)

4. Choose from 10 cones for multiple viscosity ranges

 

BGD 159 Digital Cone And Plate viscometer

المؤشرات الفنية الاساسية

Ordering Information →

Parameters ↓

BGD 159/1

(400 RPM)

BGD 159/2

(750 RPM)

BGD 159/3

(900 RPM)

BGD 159/4

(@5-1000 RPM)

Cone No.CAP-01
Shear Rate:13.3نSample Volume:67μL
47-469

ميللي باسكال

25-250

ميللي باسكال

20-208

ميللي باسكال

20-37,500

ميللي باسكال

Cone No.CAP-02
Shear Rate:13.3نSample Volume:38μL
90-938

ميللي باسكال

50-500

ميللي باسكال

40-417

ميللي باسكال

37-75,000

ميللي باسكال

Cone No.CAP-03
Shear Rate:13.3نSample Volume:24μL
180-1,875

ميللي باسكال

100-1,000

ميللي باسكال

80-833

ميللي باسكال

75-150,000

ميللي باسكال

Cone No.CAP-04
Shear Rate:3.3نSample Volume:134μL
300-3,750

ميللي باسكال

200-2,000

ميللي باسكال

170-1,667

ميللي باسكال

150-300,000

ميللي باسكال

Cone No.CAP-05
Shear Rate:3.3نSample Volume:67μL
600-7,500

ميللي باسكال

400-4,000

ميللي باسكال

300-3,333

ميللي باسكال

300-600,000

ميللي باسكال

Cone No.CAP-06
Shear Rate:3.3نSample Volume:30μL
1,500-18,750

ميللي باسكال

1,000-10,000

ميللي باسكال

800-8,333

ميللي باسكال

750-1,500,000

ميللي باسكال

Cone No.CAP-07
Shear Rate:2.0نSample Volume:1700μL
78-787

ميللي باسكال

لا يوجدلا يوجد32-63,000

ميللي باسكال

Cone No.CAP-08
Shear Rate:2.0نSample Volume:400μL
313-3,125

ميللي باسكال

لا يوجدلا يوجد125-250,000

ميللي باسكال

Cone No.CAP-09
Shear Rate:2.0نSample Volume:100μL
1,250-12,500

ميللي باسكال

لا يوجدلا يوجد500-1,000,000

ميللي باسكال

Cone No.CAP-010
Shear Rate:5.0نSample Volume:170μL
100-1,250

ميللي باسكال

لا يوجدلا يوجد50-100,000

ميللي باسكال

ملحوظة:

1. “ن”=Rotor Speed

2. Each Ordering Information has two different types according to temperature range:-5°C to 120°C (L Type) or RT+5°C to 300°C (H Type)

 

Optional accessories

THD SeriesLow Temperature Thermostatic Bath
BGD 1600Standard Oil(500ml)

BGD 1601Low Viscosity Adapter(The 0th rotor and can measure 1.0 mPa.s sample)

BGD 1602Small Sample Adapter(It’s specially designed for customers with small samples and requires only a quantity as small as 5~18mlSample cup is easily cleaned, installed, removed, and observedAccurate data of shear rate and shear stress can be obtained for a minute analysis of the fluid characteristics of the sampleOne-off sample cups are available)

BGD 1603Mini Single Color Printer

BGD 1604RTD Thermometer(-20℃~150℃)

BGD 1605Thermoses(It has been designed to accurately measure the viscosity of heated oil, paraffin, asphalt emulsions, الدواء, high polymer and similar liquid materials at high temperatures. It allows control of a sample’s temperature at a range of room temperature +300℃. It can program the intelligent thermostat and ensures its temperature fluctuation within 0.1℃. Sample dosage is as small as 10ml, and one-off sample cups are available. Standard type of SC4 spindle can be applied, which is easy to use)

BGD 1607BGD 155 Viscometer data collection and graphing software(Automated data collectionresulting in viscometer graph, and recording measuring data each timeAllowing comparison of at most 10 history dataOutput Excel documents)

BGD 1608BGD 156-157-158 Viscometer data collection and programmed analysis software(Automated data collection and testingresulting in viscometer graph, and recording measuring data each timeAllowing comparison of at most 10 history dataOutput Excel documentsProgrammable downloading, Offline workingAnalyses data, draw charts and print)

 

اتصل بنا